¹°¼ºÃøÁ¤/ÀüÀÚ°èÃø±â Àü±â/ÀüÀÚ°èÃø±âDigital Power Meter

     ¡ÞProva 6600/6601 3 Phase Power Clamp Meter

    ¡ÞTES-3063   Datalogging True RMS Power Clamp Meter     

    
¡Þ YOKOGAWA Digital Power Meter(¾Æ·¡ µµÇ¥)

Model Voltage Range Current Range Bandwidth and Accuracy Wiring
Voltage
Current
Power
WT210/
WT230
15 to 600 Vrms
(6 ranges)
Direct input: 0.5 to 20 Arms (6 ranges)
5 to 200 mArms (WT210 only)

External input: 2.5/5/10 V or 50/100/500 mV (optional)
DC, 0.5 Hz to 100 kHz

±0.2 to ±4.6%
DC, 0.5 Hz to 100 kHz

±0.2 to ±4.6%
DC, 0.5 Hz to 100 kHz

±0.2 to ±9.1%
1P2W
1P3W
3P3W
3P3W
3V3A
PZ4000 30 to 2000 Vpk
(Max.1000Vrms, 8 ranges)
Model 253751-E1: Direct input
0.1 to 10 Apk (Max. 5Arms, 7 ranges)
External input
100 m to 1000 mVpk (Max. 500 mVrms, 4 ranges)

Model 253752-E1: Direct input: 0.1 to 10 Apk (Max. 5 Arms, 7 ranges)
1 to 100 Apk (Max. 20 Arms, 7 ranges)
External input: 100 m to 1000 mVpk (Max. 500 mVrms, 4 ranges)

DC, 0.1 Hz to 5 MHz

±0.15 to 32.1%

DC, 0.1 Hz to 5 MHz

±0.15 to 32.1%

DC, 0.1 Hz to 1 MHz

±0.125 to 10.6%

1P2W
1P3W
3P3W
3P4W
3V3A
(Max 4 input module)
WT1600 1.5 to 1000 Vrms
(12 ranges)
Direct input: 10 mA to 5 A
    1 A to 50 A

External input: 50 mVrms to 10 Vrms

DC, 0.5 Hz to 1 MHz

 

±0.15 to 22.8%

DC, 0.5 Hz to 1 MHz
DC, 0.5 Hz to 100 kHz

±0.15 to 22.8%
±0.15 to 10.4%

DC, 0.5 Hz to 1 MHz
DC, 0.5 Hz to 100 kHz

±0.15 to 49%
±0.15 to 20.8%

1P2W
1P3W
3P3W
3P4W
3V3A
WT130 15 to 600 Vrms
(6 ranges)
Direct input: 0.5 to 20 Arms (6 ranges)

External input: 50,100,200 mVrms or 2.5,5,10 Vrms (3 ranges)

DC, 10 Hz to 50 kHz

±0.25 to ±7%

DC, 10 Hz to 50 kHz

±0.25 to ±7%

DC, 10 Hz to 50 kHz

±0.35 to ±11.6%

1P2W
1P3W
3P3W
3P3W
3V3A
WT200 15 to 600 Vrms
(6 ranges)
Direct input: 5 mArms to 20 Arms (12 ranges)

External input: 50,100,200 mVrms or 2.5,5,10 Vrms (3 ranges)

DC, 10 Hz to 50 kHz

±0.25 to ±7%

DC, 10 Hz to 50 kHz

±0.25 to ±7%

DC, 10 Hz to 50 kHz

±0.3 to ±11.6%

IP2W
WT1000 15 to 1000 Vrms
(8 ranges)
Direct input: 0.5 to 20 Arms (6 ranges)

External input: 250 mVrms to 10 Vrms (6 ranges)

DC, 0.5 Hz to 300 kHz

±0.2 to 29%

DC, 0.5 Hz to 300 kHz

±0.2 to 29%

DC, 0.5 Hz to 200 kHz

±0.2 to 29%

1P2W
1P3W
3P3W
3P4W
3V3A
WT2000 10 to 600 Vrms
(8 ranges)
Direct input: 1 to 30 Arms (6 ranges)

External input: 50,100,200 mVrms (3 ranges)

DC, 2 Hz to 500 kHz

±0.06 to 16.5%

DC, 2 Hz to 500 kHz

±0.06 to 16.5%

DC, 2 Hz to 300 kHz

±0.08 to 27%

1P2W
1P3W
3P3W
3P4W
3V3A

  Clamp on Power Meter CW120
  Clamp on Power Meter CW140

Digital Multimeters

Model

Max.
display

Sample
rate

Range mode

DC V
range /
accuracy

OHM range/
accuracy

AC V
range/
accuracy

DC A
range/
accuracy

AC A
range/
accuracy

Comm.

7561
/7562

1999999
(6×1/2 digit)

333ȸ/s
(4digit)
40ȸ/s
(5digit)
4.8ȸ/s
(6digit)

Auto/
Manual

200mV
~1000V
(5ranges)/
±0.003%
(0.01¥ìV)

200¥Ø
~200M¥Ø
(7ranges)/
±0.009%
(0.1m¥Ø)

200mV
~700V
(5ranges)/
±0.15%

2mA
~2,000mA
(4ranges)/
±0.05% 

2mA
~2,000mA
(4ranges)
(20A´Â7562
¿¡ ÇØ´ç)/
±0.5%

GP-IB
¶Ç´Â
RS-232-C

7555

199999
(5×1/2 digit)

2ȸ/s,
4ȸ/s,
20ȸ/s,
125ȸ/s

Auto/
Manual

200mV
~1000V
/
±0.0055%
(1¥ìV)
  

200¥Ø
~200M¥Ø/
±0.008%
(0.1m¥Ø) 

200mV
~700V/
±0.9%

2000¥ìA
~2000mA/
±0.06%  

20mA
~2000mA/
±1.3%  

GP-IB
¶Ç´Â
RS-232-C

   Digital Resistance Meter 7556

  Programmable Scanner

   Programmable Scanner 7501

                  °èÃø±âÀüü¸Þ´º 