TES-3063 |
|
¡ÜDatalogging True RMS Power Clamp
Meter TES-3063(RS-232, RMS) ¡ÜRS-232 interface to talk with PC
¡Ü4000 Continuity Point Data Logger, 25 point manual Data Logger
¡ÜTrue Power / Apparent Power / Power Factor Measurement
¡ÜTrue RMS, V, A, W, lead, lag PF indicator ¡Ü4 digits with dual Display LCD
¡ÜMIN / MAX Measurement
¡ÜAmp / Voltage Frequency Measurement
¡ÜPEAK HOLD Detector
¡ÜDual display KW+PF, KVA+PF, V+A
¡ÜDual display A+Hz, V+Hz | |
|
ELECTRICAL SPECIFICATIONS : (23¡É±5¡É)
¡á True
Power & Apparent power measurement
Input |
Resolution |
Accuracy |
Frequency
range |
Overload
protection |
V<130V, A<150A |
0.01 |
±(2%+5) |
45Hz - 500Hz |
600V/1100A |
V>130V, A<150A |
V<130V, A>150A |
V>130V, A>150A |
0.1 |
±(2%+1) |
¡á DCA
Range |
Resolution |
Accuracy |
Overload
protection |
1000A |
0.1A |
±(1.5%rdg + 5dgts) |
1100A |
¡á ACA
Range |
Resolution |
Accuracy |
Frequency
range |
Overload
protection |
1000A |
0.1A |
±(1.5%rdg + 5dgts) |
45Hz~500Hz |
1100A |
¡Ø Crest Factor : 4 for stated accuracy
¡á DCV
Range |
Resolution |
Accuracy |
Input
Impedance |
Overload
protection |
600V |
0.1V |
±(0.5%rdg + 5dgts) |
1M§Ù |
600V |
¡á ACV
Range |
Resolution |
Accuracy |
Input
Impedance |
Frequency
range |
Overload
protection |
600V |
0.1V |
±(0.5%rdg + 5dgts) |
1M§Ù |
45Hz~500Hz |
600Vms |
¡Ø Crest Factor : 3 for stated accuracy
¡á Peak
Indication
Range |
Resolution |
Accuracy |
Overload
protection |
20A~80A |
0.1A |
±(10%rdg + 10dgts) |
1100A |
80A~1000A |
±(6%rdg + 10dgts) |
¡Ø Peak Detect Acquisitions Time ¡Â 1ms
¡á Peak
Indication
Range |
Resolution |
Accuracy |
Overload protection |
20V~80V |
0.1V |
±(10%rdg + 10dgts) |
600Vrms |
80V~600V |
±(6%rdg + 10dgts) |
¡Ø Peak Detect Acquisitions Time ¡Â 1ms
¡á Audible continuity
Range |
Continuity beeper |
Open circuit voltage |
Overload protection |
|
¡Â 0.050 |
¡Â 3.2V |
600Vrms |
¡á Resistance(§Ù)
Range |
Resolution |
Accuracy |
Open circuit voltage |
Overload
protection |
10K§Ù |
1§Ù |
±(1%rdg + 5dgts) |
¡Â 3.2V |
600Vrms |
¡á Diode test
Range |
Resolution |
Overload protection |
|
0.001V |
600Vrms |
¡á Frequency (Hz)
Range |
Resolution |
Accuracy |
Voltage
sensitivity |
Overload
protection |
1KHz |
0.1Hz |
±(0.5%rdg + 5dgts) |
10V or 10A |
600V/1100A |
5KHz |
1Hz |
GENERAL SPECIFICATIONS :
- Maximum Voltage between any terminal and earth ground :
600Vrms
- Numerical Dual Display : 4 digit liquid crystal display (LCD)
maximum reading 9999
- Bargraph display : 40 Segments
- Battery Life : 30hr approx.(Alkaline)
- Jaw Opening Diameter : Cables ¥Õ46mm
- Operating Temperature and Humidity :
0¡É to 50¡É(32¢µ to 122¢µ) R.H. < 80%
non-condensing
- Storage Temperature and Humidity :
-10¡É
to 60¡É(14¢µ to 140¢µ) R.H. < 70% non-condensing
- Dimensions : 260mm(L) x 93mm(W) x 45mm(H)
- Weight : Approx. 450g
- Accessories : Carrying Case, Test leads, Alligator clip, Battery
& Instruction manual
- Optional Accessories : RS-232 Interface & software
(TES-3064)
|
|
°èÃø±âÀüü¸Þ´º welcome to sjscale@naver.com
Àú¿ï ¹× °èÃø±â±âÀÇ ¸ðµç
°Í(½ÅÁ¤Á¤¹Ð±â°è)
(Tel:055-237-5300~2,FaX:055-237-5007) |