Max. capacity |
kgf |
20, 50, 100, 200, 300, 400 |
Rated output Zoro balance |
mV/ V mV/ V |
2.0 ± 0.2 0 ± 0.1 |
Combined error Repeatability Creep for
30min. Temperature effect on Zero Value Output
value |
% % %
%/ 10¡É %/ 10¡É
|
0.05 0.05 0.03
0.05 0.05 |
Excitation Recommended Maximum Resistance Input Output Insulation
|
V V
¥Ø ¥Ø M¥Ø |
10 15
700 ± 10 700 ± 5 £¾2,000 |
Compensated temperature range Operating temperature
range |
¡É ¡É |
-10 to +40 -30 to +80 |
°èÃø±âÀüü¸Þ´º
welcome to sjscale@naver.com
Àú¿ï ¹× °èÃø±â±âÀÇ ¸ðµç
°Í(½ÅÁ¤Á¤¹Ð±â°è)
(Tel:055-237-5300~2, FaX:055-237-5007) |