Max. capacity |
kgf |
100, 150, 250, 300, 500 |
Rated output Zoro balance |
mV/ V mV/ V |
2.0 ± 0.2 0 ± 0.1 |
Combined error Repeatability Creep for
30min. Temperature effect on Zero Value Output
value |
% % %
%/ 10¡É %/ 10¡É
|
0.03 0.01 0.03
0.028 0.014 |
Excitation Recommended Maximum Resistance Input Output Insulation
|
V V
¥Ø ¥Ø M¥Ø |
10 15
400 ± 20 350 ± 3.5 £¾2,000 |
Compensated temperature range Operating temperature
range |
¡É ¡É |
-10 to +40 -20 to +70 | |