BC-X, BC-SS Single point load cell 60, 150, 300kgf Water proof type Off center compensated Protection class IP66 All
stainless steel construction(BC-SS)
Material |
SSocket-head cap screw M8 1.25(10.9) Tightening torque : 29Nm |
Mounting |
Socket-head cap screw M3 0.5(10.9) Tightening torque: 1.5Nm
|
Cable |
Braided Shield 4-wire round cable with PVC-Jacket
|
ÃÖ´ëPlatform Size |
400 600mm(W L) |
Ordering Information |
BC - 00X ¦³ Capacity in kg
|
BC -
XXXSS ¦¬¦³ Capacity in kg |
|
Max. capacity |
kgf |
60, 150, 300 |
Rated output Zoro balance |
mV/ V mV/ V |
1.2 ± 10% R.O 0 ± 10% R.O |
Accuracy class |
|
C3 (BC-X) |
Combined error Repeatability Creep for
30min. Temperature effect on Zero Value Output
value |
% % %
%/ 10¡É %/ 10¡É
|
£¼0.02 £¼0.01 £¼0.017
0.014 0.011 |
Excitation Recommended Maximum Resistance Input Output Insulation
|
V V
¥Ø ¥Ø M¥Ø |
10 15
420±20 350±3.5 £¾2,000 |
Compensated temperature range Operating temperature
range |
¡É ¡É |
-10 to +40 -20 to +70 |
°èÃø±âÀüü¸Þ´º
welcome to sjscale@naver.com
Àú¿ï ¹× °èÃø±â±âÀÇ ¸ðµç
°Í(½ÅÁ¤Á¤¹Ð±â°è)
(Tel:055-237-5300~2, FaX:055-237-5007) |
|
|