 Viscometer Accessories

   
 

1. ¼Ò·®½Ã·á Á¡µµÃøÁ¤À» À§ÇÑ SMALL SAMPLE ADAPTER

Small Sample Adapter´Â ¿øÅëÇü sample chamber¿Í spindle·Î
   ±¸¼ºµÇ¸ç, 2~16mlÀÇ ÀûÀº ½Ã·á·®À¸·Î Á¤È®ÇÑ Á¡µµ ÃøÁ¤¿¡
   ÀûÇÕÇÑ Àåºñ·Î¼­ ÀÌ Àåºñ ¿ª½Ã Cone/Plate Á¡µµ°è¸¦ Á¦¿ÜÇÑ
   Àü ¸ðµ¨¿¡ »ç¿ë °¡´ÉÇÕ´Ï´Ù.








(1) Ư¡

2~16mlÀÇ ¼Ò·® ½Ã·á·Î¼­ Á¡µµ ÃøÁ¤ ¹× rheological Ư¼º ºÐ¼® °¡´É
Å»Âø °¡´ÉÇÑ sample chamber·Î ±³È¯ ¹× ¼¼Ã´¿ëÀÌ
Á¡µµ ¹üÀ§¿¡ µû¶ó spindle·Î ¼±Åà °¡´É
Jacket typeÀ¸·Î water bathÀÌ¿ë½Ã Á¤È®ÇÑ ¿Âµµ Á¶Àý °¡´É
Brookfield¸ðµç Ç¥ÁØ Á¡µµ°è¿¡ ºÎÂø °¡´É
Option RTD ¿Âµµ probe¸¦ sample chamber¿¡ Á÷Á¢ ¿¬°áÇÏ¿© ½Ã·áÀÇ Á¤È®ÇÑ ¿Âµµ ÃøÁ¤ °¡´É

 

2. ÀúÁ¡µµ ÃøÁ¤À» À§ÇÑ UL ADAPTER

Brookfield UL Adapter´Â Brookfield Á¡µµ°è¿¡ ºÎÂøÇÏ¿© ¸Å¿ì ³·Àº
   Á¡µµ¸¦ °®´Â ¹°ÁúµéÀÇ Á¤È®ÇÑ Á¡µµ ÃøÁ¤À» À§ÇÑ Àåºñ·Î¼­
   Cone/Plate Á¡µµ°è¸¦ Á¦¿ÜÇÑ Brookfield»çÀÇ ¸ðµç Á¡µµ°è¿¡ ºÎÂøÇÏ¿©
   »ç¿ëÇÒ ¼ö ÀÖÀ¸³ª ÁÖ·Î LV typeÀÇ ¸ðµ¨¿¡ °¡Àå ¸¹ÀÌ »ç¿ëµË´Ï´Ù.
   LV¸ðµ¨ Á¡µµ°è¿¡¼­ ÃøÁ¤¹üÀ§´Â 1-2000cpsÀÔ´Ï´Ù.

(1) Ư¡

Á¤¹ÐÇÏ°Ô Á¦Á¶µÈ spindle°ú sample chamber
Á¤È®ÇÑ Á¡µµ ÃøÁ¤
DIN 53019¿¡ ÀÇÇÑ DIN spindle»ç¿ë °¡´É
¼Ò·®ÀÇ ½Ã·á»ç¿ë(16ml, DIN spindleÀÇ °æ¿ì 17ml)
ULA-40Y water jacket»ç¿ë½Ã Á¤È®ÇÑ ¿Âµµ Á¶Àý
-15~100 ¡É¿Âµµ¿¡¼­ ÃøÁ¤ °¡´É
Stainlsee steel·Î ºÎ½ÄÀÇ À§ÇèÀÌ ¾øÀ¸¸ç ¼¼Ã´ ¿ëÀÌ

 


3.Non-flowing ¹°ÁúÀÇ Á¡µµÃøÁ¤À» À§ÇÑ HELIPATH STAND

Helipath stand´Â ºñÀ¯µ¿¼º ¹°Áú, Áï gel,pasteÇüÅÂÀÇ ¹°ÁúÀÇ
   Á¡µµ ÃøÁ¤¿¡ À¯¿ëÇÑ ÀåºñÀÔ´Ï´Ù. ÀÌ·¯ÇÑ ¹°ÁúÀº disc spindleÀ̳ª
   coaxial spindle»ç¿ë½Ã channelingÀ» ÀÏÀ¸Å°¹Ç·Î
   Á¤È®ÇÑ Á¡µµ ÃøÁ¤ÀÌ ¾î·Æ½À´Ï´Ù. À̶§, T-bar spindle°ú Helipath
   stand¸¦ »ç¿ëÇϸé spindleÀÌ È¸ÀüÇϸ鼭 Á¡µµ°è°¡ »óÇÏ·Î
   ¿òÁ÷À̹ǷΠT-bar spindleÀº Ç×»ó »õ·Î¿î ½Ã·á¿Í Á¢ÃËÇÏ°Ô µÇ¸ç
   µû¶ó¼­ º¸´Ù Á¤È®ÇÑ Á¡µµÀÇ ÃøÁ¤ÀÌ °¡´ÉÇÕ´Ï´Ù.
   Helipath stand´Â 6°³ÀÇ T-bar spindleÀÌ ±âº»À¸·Î °ø±ÞµË´Ï´Ù.

 

 


4.Viscosity Standards(Ç¥ÁØÁ¡µµ ¿ë¾×)

Ưº°ÁÖ¹®¾×ü
    25 ¡É(77°F)¿¡¼­ ±³Á¤µÈ ¿ë¾×¿ÜÀÇ Á¡µµ¿¡ ´ëÇؼ­ ÁÖ¹® ÇÒ ¼ö ÀÖ´Ù.
    ÃÖ¼Ò:5cP

    ÃÖ´ë: 60,000cP






25¡É(77°F)¿¡¼­ ±³Á¤µÈ STOCK FLUIDS

Fluid cP(mPa.S)
Specific Gravity
Fluid cP(mPa.S)
Specific Gravity
5
0.920
5,000
0.972
10
0.940
12,500
0.973
50
0.960
30,000
0.973
100
0.968
60,000
0.973
500
0.972
100,000
1,000
1,000
0.972
-
-

¿Âµµ±³Á¤
   Àç°í ¶Ç´Â È¥ÇÕ¾×ü´Â 25¡É(77°F)¿ÜÀÇ ¿Âµµ¿¡¼­ ±³Á¤µÉ ¼ö ÀÖ´Ù. ÃÖ¼Ò: 20¡É(68°F) ÃÖ´ë:80¡É
    (176°F)

°í¿Â¾×ü
   ÀÌ ¾×ü´Â Brookfield Thermosel ½Ã½ºÅÛ°ú °°ÀÌ »ç¿ëÇϱ⸦ ±ÇÇÕ´Ï´Ù.

Fluid
Temperature
Nominal Viscosity cP(MPa.s)
¡É
°F
HT 30,000
25
93.3
149
77
200
300
30,000
9,000
4,500
HT 60,000
25
93.3
149
77
200
300
60,000
18,000
9,000
HT 100,000
25
93.3
149
77
200
300
10,000
30,000
15,000

  5. Thermosel System (Á¤¿ÂÀåÄ¡ - °í¿Â¿ë Á¡µµ ÃøÁ¤ ½Ã½ºÅÛ)
  (1) Ư¡

1) System 1 : Dial Reading Viscometer, Temperature Controller (Model 75)
2) System 2 : Temperature Controller (Model 75), Model DV-I+ (Shown), Recorded Output
3) System 3 : Recorded Output, Model DV-III (Shown),
                     Programmable Temperature Controller (Model 106)

ºÐ¼® ½Ã·áÀÇ Pseudoplastic/thixotropic Ư¼º ºÐ¼® °¡´É
±2% ÀçÇö¼º
BrookfieldÀÇ ¸ðµç Ç¥ÁØ Á¡µµ°è¿¡ ºÎÂø »ç¿ë °¡´É
°£ÆíÇÑ ¼³Ä¡ ¹× ½Å¼ÓÇÑ Á¡µµ ÃøÁ¤
¼¼Ã´¿ëÀÌ


  6. RHEOCALC Software
 


(1) FEATURES/BENEFITS
Automates data collection
Eliminates operator error when recording data
Provides instaneous viscosity flow curves(rheograms) on
     easy-to-read graphs
Creats a permanent record of each test
Up to 5 data sets may be plotted simultaneously
Plot data available:% torque,rpm,viscosity,,shear rate,shear
    stress,temperature,time
Yield stress calculations(Bingham Plastic, Casson, Chocolate Casson),
    power law consistency index calculations,paste analysis
For use with the DV-III+ and DV-III Rheometers
(2) DATA COLLECTION MODES
Powerful scripting language provides simple to complex data collection programs
Wait for events to occur
Complete speed/shear rate control of rheometer
Complete sample temperature control(using optional temperature controller)
Variable data collection intervals
Save data during a program run
Looping functions for repetitive tasks

  7. Á¤¹Ð Ç׿¼öÁ¶
 

For use at lower temperatures,use the built-in tap water cooling coil, or use the model TC-351
    Cooler for control to -20 ¡É For Temperatures Higher than 80¡É, Please Contact Brookfield
    for fluid recommendations.

 


MODEL

TC-501P

TC-501D

TC-101P

TC-101D

TC-201P

TC-201D

Controller

Programmable

Digital

Programmable

Digital

Programmable

Digital

Temperature Minimum
Temperature
Maximum

-20¡É
200¡É

-20¡É
150¡É

ambient +5¡É
200¡É

ambient +5¡É x
150¡É

ambient +5¡É x
150¡É

ambient +5¡É x
150¡É

Temperature Stability

±0.01¡É

±0.05¡É

±0.01¡É

±0.05¡É

±0.01¡É

±0.05¡É

Readout
Accuracy

LCD,±0.25¡É

LCD,±0.05¡É

LCD,±0.25¡É

LCD,±0.05¡É

LCD,±0.25¡É

LCD,±0.05¡É

Heater

1000Watts

1000Watts

1000Watts

Reservoir Capacity

6 liters

6 liters

10 liters

Pump
Capacity

11 to 24 lpm

9 or 15 lpm

11 to 24 lpm

9 or 15 lpm

11 to 24 lpm

9 or 15 lpm

Pump
Inlet & Outlet

1/4 in.Int.NPT

1/4 in.Int.NPT

1/4 in.Int.NPT

Internal Work Area
I x w x d (cm)

13.3 x 13.3 x 14cm

13.3 x 13.3 x 14cm

13.3 x 21.6 x 19.7 cm

Overall Dimensions
h x w x d (cm)

40 x 47.6 x 43.2 cm

37.5 x 21 x 35.6 cm

39.4 x 27.6 x 37.5 cm

Shipping Weight

76 Ibs / 34.5kg

27 Ibs / 12.3 kg

37 Ibs / 16.8 kg

Electrical Requirements

120V,60 Hz,10A
240V,50Hz,5A

120V,50-60 Hz,9A
240V,50-60Hz,4.5A

120V,50-60 Hz,9A
240V,50-60Hz,4.5A

 