UP
left
ÁÖ¹®Á¦ÀÛ
ÀüÀÚÀú¿ï
Á¤¹Ð Balance

°¢Á¾ °èÃø±â±â

°¢Á¾ ÃøÁ¤°ø±¸

»ê¾÷¿ëÀüÀÚÀú¿ï
»ó¾÷¿ëÀüÀÚÀú¿ï
Å©·¹ÀνºÄÉÀÏ
·Îµå¼¿
ÀεðÄÉÀÌÅÍ
ÇÁ¸°ÅÍ

ÃàÁß±â(À±Áß±â)

½ÅÀåÀÚµ¿ÃøÁ¤±â¹×
üÁß°è,°Ç°­º¸Á¶±â
¼öµ¿Àú¿ï¹×±âŸÀú¿ï
¼ö·Ïȸ»çº¸±â
³¯¾¾Á¤º¸
Àá°£ ½¬¾î °¡±â

NAVER.COM


¿©±æ¸¦ Ŭ¸¯Çϼ¼¿ä

  

 

 

 

 

ȯ°æ°ü·Ã ÃøÁ¤±â±â¼öÁú°ü·Ã±â±âÀÌ¿ÂÃøÁ¤±âIM-5005

 

 

IM-5005

 

¡Ü °ø±âÁß À½ÀÌ¿Â/¾çÀÌ¿ÂÀ» 0~5,000,000°³/cm³ ±îÁö ±¤¹üÀ§ÇÑ ÃøÁ¤ÀÌ °¡´É
¡Ü ÀÚµ¿ ÃøÁ¤ ¹üÀ§ Àüȯ ±â´ÉÀ» ³»ÀåÇÏ°í ÀÖ¾î ÃøÁ¤ ½Ã Ç×»ó ÀûÀýÇÑ ÃøÁ¤¹üÀ§·Î ÃøÁ¤ÀÌ °¡´É
¡Ü
ÀÚµ¿ ¿µÁ¡ ±³Á¤ ±â´ÉÀ» °®°í ÀÖ¾î Àú³óµµ¿¡¼­µµ ÃøÁ¤ÀÌ °¡´É
¡Ü ¼³Á¤ÇÑ ½Ã°£°£°ÝÀ¸·Î À½ÀÌ¿Â/¾çÀÌ¿Â ÃøÁ¤À» ÀÚµ¿À¸·Î ÀüȯÇϸç ÃøÁ¤ÀÌ °¡´É
¡Ü 12,790°³±îÁö ÃøÁ¤µ¥ÀÌÅ͸¦ ¼³Á¤ÇÑ ½Ã°£ Áֱ⠰£°ÝÀ¸·Î ÀúÀå
¡Ü ´ëÇü ¾Æ³î·Î±×Ç¥½Ã±â¿Í µðÁöÅÐ LCD·Î ÃøÁ¤Ä¡¸¦ Ç¥½ÃÇϹǷΠÃøÁ¤Ä¡¸¦ ÀбⰡ Æí¸®ÇÔ
¡Ü ¼ÒÇü °æ·®À̸ç, ÃæÀü¿ë °ÇÀüÁö¸¦ ³»ÀåÇÏ°í ÀÖ¾î 6½Ã°£±îÁö ¿¬¼Ó ÈÞ´ë ÃøÁ¤ÀÌ °¡´É
¡Ü ¿ÜºÎ¿É¼Ç ¼¾¼­(¿¹:¿Â½Àµµ ¼¾¼­µî)¿Í ¿¬°áÇÏ¿© µ¿½Ã¿¡ µ¥ÀÌÅÍ ÀúÀåµµ °¡´É
¡Ü ±â·Ï¿ë ¾Æ³ª·Î±× Ãâ·Â ¹× RS-232C Ãâ·ÂÀ» Áö¿øÇÏ°í ÀÖ¾î Á¦°øµÇ´Â ºÐ¼®¿ë ¼ÒÇÁÆ®¿þ¾î·Î PC¿¡¼­ µ¥ÀÌ
    ÅÍ Ã³¸® ¹× ºÐ¼®ÀÌ °¡´É
¡Ü °ø±âÁßÀÇ À½ÀÌ¿Â/¾çÀÌ¿Â Á¤¹ÐÃøÁ¤ ¹× ¿¬±¸ºÐ¼®¿ëÀ¸·Î °³¹ßÇÑ ÃֽűâÁ¾

 

The Measuring-System is built up of an external tubular electrode (1) a smaller electrode (2) and a ventilator (3) mounted within.  Between the electrodes a DC potential (4) of 60 Volt is applied. This creates an electric field between the electrodes. The ventilator (3) draws air continuously at a defined volumetric quantity through the tube. The electric field between the electrodes deflects the ions in the passing air to the inner electrode. At resistors of high impedance (5) (up to 1011 Ohm) the charging current generated by the charge neutralising will lead to a measurable voltage.

This signal, which is proportional to the concentration of ions in the air can then be processed with an adequate amplifier (6).
The signal can then be used for:
lthe output of the readings at the Analogue Display (7)
lthe Analogue Line Out (8) lthe internal Analogue/Digital Converter for data logging and output of data via the serial port

  

±â     ´É

±Ô     °Ý

¸ðµ¨

IM-5005

ÃøÁ¤ÀÌ¿Â

À½ÀÌ¿Â/¾çÀÌ¿Â

ÃøÁ¤¹üÀ§

0~5--/5,000/50,000/500,000/5,000,000°³/cm³ (9-range)
(ÀÚµ¿ÃøÁ¤¹üÀ§ ÀüÈ­±â´É ³»Àå)

Ç¥½ÃºÐÇØ´É

1°³/cm³ (0~500°³/cm³ ¹üÀ§¿¡¼­)¶Ç´Â ÃøÁ¤¹üÀ§ÀÇ 1/5,000´ÜÀ§

¿µÁ¡Á¶Á¤

ÀÚµ¿ ¹× ¼öµ¿ ¿µÁ¤±â´É Áö¿ø

À̿¼±ÅÃ

¼öµ¿ ¹× Timer±â´É¿¡ ÀÇÇÑ ÀÚµ¿ Àüȯ

Warm-up½Ã°£

Æò±Õ 5ºÐ

µ¥ÀÌÅÍ ÀúÀå

12,790°³±îÁö µ¥ÀÌÅÍ ÀúÀå°¡´É(ÀúÀåÁֱ⠼³Á¤ °¡´É)

Ç¥½Ã¹æ½Ä

´ëÇü ¾Æ³¯·Î±× Áö½Ã°è ¹× µðÁöÅÐ LCD Ç¥½Ã

¿ÜºÎÀÔ·Â

¾Æ³¯·Î±× ÀÔ·Â(-10~+10V DC ÀԷ´ÜÀÚ 1°³)/RS485ÀÔ·Â
(16°³ ¼¾¼­ÀÔ·Â °¡´É)

Ãâ·Â¹æ½Ä

µðÁöÅÐ Ãâ·Â(RS-232C Ãâ·Â)/¾Æ³¯·Î±× Ãâ·Â (0~1/2.5/5/10V DCÃâ·Â)

½Ã°è±â´É

½Ç½Ã°£ Ç¥½Ã ¹× ¼³Á¤ °¡´É

¼ÒÇÁÆ®¿þ¾î ±â´É

½Ç½Ã°£ µ¥ÀÌÅÍ ¹× ÀúÀå µ¥ÀÌÅÍ °ü¸®

»ç¿ë¿Âµµ

0~40°c

»ç¿ëÀü¿ø

AC 220V ¾Æ´äÅÍ(DC12V)

º¸Á¶Àü¿ø

AC 220V ÃæÀü Adaptor(12V)¶Ç´Â ÃæÀüÁö(¾à6½Ã°£ »ç¿ë)

Å©±â

320×220×145mm

¹«°Ô

¾à 5kg

         °èÃø±âÀüü¸Þ´º

                                   welcome to sjscale@naver.com        
                           
   Àú¿ï ¹× °èÃø±â±âÀÇ ¸ðµç °Í(½ÅÁ¤Á¤¹Ð±â°è) 
            
            (Tel:055-237-5300~2,  FaX:055-237-5007)