SAS Super 100

SAS IAQ

SAS Super 100,SAS IAQ

 

¡Ü½Ç³» °ø±âÁú ¹× ´ë±â °øÁ¾½ÃÇè¹ü¿¡ ±ÔÁ¤µÈ ¹æ½ÄÀ»  Ã¤¿ëÇÑ ºÎÀ¯¼¼±Õ Æ÷Áý±â·Î ¹ÙÀÌ·¯½º, °õÆÎÀÌ,
  ¹ÚÅ׸®¾Æ µîÀ» Æ÷ÁýÇϱ⿡ ÀûÇÕÇÕ´Ï´Ù.
¡Ü½ºÅ×Àη¹½º Çìµå¸¦ ÀåÂøÇÏ°í ÀÖ¾î ¹ÝµµÃ¼, ÀǾàºÐ¾ß, ½ÄÇ° ºÐ¾ß, ÃÊÁ¤¹Ð ºÎÇ° ºÐ¾ß µî¿¡¼­ ¿î¿µÇÏ´Â
   Å©¸°·ë¿¡¼­µµ »ç¿ëÀÌ °¡´ÉÇÑ Æ÷Áý±âÀÔ´Ï´Ù.

 
The ¡°SAS – 100¡± has the following new features:
• Performance in compliance with ISO 14698-1
• Large LCD with illuminated touch panel
• All operator commands via touch keypad for easier cleaning
• Over 70.000 litres of air / 8 hours autonomy
• Infrared transfer of sampling data to PC or printer
• Up to 300 sampling cycles memorised
• USP chapter < 1116 > and 21-CFR 11 Compliance
• Sampling rate accurately maintained by speed sensor-incorrect aspiration aborts cycle
• Design avoids turbulence in unidirectional air flow and re-aspiration of tested air in accordance
  with ISO specifications
• Total traceability
• Bi-directional port to input and output data to a central unit from 1 to 24 samplers
• Calibration system by finger-tip control without opening the instrument
• Automatic calibration reminder
• Easy calibration monitoring with additional anemometer system
• Sampler can be operated whilst attached to mains
 
The SAS IAQ features:
• Volume of aspirated air programmable from 1 to over 1000 litres
• Air flow rate 100 litres of per minute
• It uses RODAC Contact plates or Standard 90 mm Petri dishes
• Can accommodate any type of Contact plate (US or European shape)
• Reduced weight: only 1,400 grams
• Robust construction for use in industrial environments
• Autonomy over 40,000 litres (6 hours)


¡Ü½Ç³»°ø±â ¹× ´ë±â ÁßÀÇ ºÎÀ¯ ¼¼±º Æ÷Áý¿ë
¡Ü»ê¾÷À§»ý ºÐ¾ß, °øÁ¶ºÐ¾ßÀÇ À§»ý°ü¸®¿ë
¡Ü½ÄÇ°°¡°ø ¹× Á¦Á¶¾÷ü, À¯Åë¾÷üÀÇ HACCP ±âÁØ °ü¸®¿ë
¡Ü¹ÝµµÃ¼, Á¦¾àȸ»ç, ÀÇ·á±â°üµî Å©¸°·ëÀÇ ºÎÀ¯¼¼±Õ Æ÷Áý¿ë
¡Üȯ°æ ´ëÇà ¹× ¿ë¿ª¾÷üÀÇ ºÎÀ¯¼¼±Õ Æ÷Áý¿ë

  

Model

SAS Super 100

SAS Super 180

SAS IAQ

Catalogue No.

86279
86834

37565

 Flow rate

100§¤/min

180§¤/min

100§¤/min

Time to collect
1 cubic metre

1,000§¤/10min

1,000§¤/6min

1,000§¤/10min

 Æ÷ÁýÇìµå

55mm Petri-dishs

90mm Petri-dishs

90mm Petri-dishs

 Æ÷ Áý ·®

Autonomy Over 70.000 litres(8 hours)

Autonomy over 40,000 litres (6 hours)

 Àü      ¿ø

Ni-MH ÃæÀü±â (¾à6~7½Ã°£ »ç¿ë)

 Å©±â.¹«°Ô

 304×74×110mm/¾à1.8kg

  112×286×156mm/¾à1.4kg

 ¿É¼Ç

 Ç¥ÁØ Case, Battery charge(220V)
SAS Softwatre(µ¥ÀÌÅÍ°ü¸®¿ë)

 Ç¥ÁØ Case,Battery charge(220V)

 

 90mm Petri-dishs °¡´É

 