¿©±æ¸¦ Ŭ¸¯Çϼ¼¿ä

  

 

 

 ¹°¼ºÃøÁ¤/ÀüÀÚ°èÃø±âÀü±â/ÀüÀÚ°èÃø±âRecorder
                              
KL-100(Paperless Recorder)

  

KN-100

 

¡Ü Paperless type
¡Ü Touch screen ¹æ½ÄÀ¸·Î ÀÌ¿ë °£Æí
¡Ü ±â·ÏÁö ´ë½Å¿¡ 3.5ÀÎÄ¡
floppy disk ³ª ZIP, 8MB Internal flash memory¿¡ data ÀúÀå
¡Ü RS232³ª RS485Åë½ÅÀ» ±âº»À¸·Î, option ¼±Åýà Ethernet Ä«µå¸¦ ÅëÇÑ networking °¡´É
¡Ü Display : Vertical Trend, Horizontal Trend, Bargraph, Digital, Alarm summary, Bit map display, Overview
    µîÀ¸·Î ÀÚÀ¯·ÎÀÌ º¯°æ°¡´É


INPUT

 Number

6, 12 or 18 isolated inputs

 Type

 

DC Voltage

Linear amd square root programmable to 10 VDC
(50mV, 100mV, 200mV, 1V, 5B and 10V bipolar ranges)

DC Current

linear, square root and log programmable to 4-20mA, 10-50mA and dry contact

T/C

J,K,T,E,R,S,B,C, Nicrosil Nisil and Nickel/Nickel Moly

RTD

10 ¥Ø Cu, 100 ¥Ø Pt 385, 100 ¥Ø Pt 392, 200 ¥Ø Pt 385, 200 ¥Ø Pt 392 and 120 ¥Ø Ni

Extermal

computer generated

 Accuracy

 

 

Voltage

 ±0.05% of programmed range

Current

 ± 1% using external shunt resistor

T/C

 ± 1.5 ¡É for JKTE Nicrosil-Nisil and Nickerl/Cickel Moly ; ±3 ¡É for R, S and C; ±4¡É for B

RTD

± 0.5 % ¡É

Resolution

 

 0.006% of Full Scale

Impedance

 

 >10M ¥Ø

Scan Rates

 

All points scanned every 125mS

RECORDING

Rates

 

8 Samples/Second to 1 Sample/Minute

Intermal Memory

 

16 MB of RAM and 8MB of Flash

Starage Media

 

3.5" floppy disk, PCMCIA ATA flash or Zip disk

DISPLAY

Type

 

 5.5" Color active Matrix TFT LCD(320×240)

Display Modes

 

   Up to 8 user difined screens(Vertical Trend, horizontal Trend, Bargrach, Digital, Overview, Alarm/Event Summaary, Bitmap Display )

Display colors

 

Up to 16 colors

Update Rate

 

125mS

Virtical Chart Speed

 

User programmavle in inches or mm per hour

Virual Chart Scales

 

User programmable

ALARM FUNCTIONS

Number

 

   Up to 5 alarm setpoints per point

Types

 

 H, L, Rate, Abnormal

Contact Output/Input

 

  6 isolated Form C contacts output and 6 digital inputs per card.
  1 amp @ 250 VAC or 26 VDC

Deadband/Failsafe

 

 User selectable

POWER

Requirements

 

  100 to 240 VAC(50 to 60 Hz) or 90 to 125 VDC or 18 to 30 VDC

COMMUNICATIONS

Serial Ports

 

  Dual RS232/RS485 Communications w/ MODBUS(RTU or ASCII)

Porallel Printer Port

 

Screen Print, Alarm/interval/Time of day Logs

Network Type

 

Ethernet(10 Base-T), TCP/IP Protocol

ENVITONMENTAL

Temperature

 

-10 to 50 ¡É

Operating humidity

 

10% to 90% RH non-condensing

Enclosure

 

IP65 Front Panel

Dimensions

 

Bezel : 144mm×144mm/Cutout : 138 mm × 138 mm
Depth : 9.25"

Weight

 

7.5 Ibs (Estimate : varies depending upon model)