ELECTRICAL SPECIFICATIONS : (23℃±5℃)
■ Insulation Resistance : Range : 1000MΩ/250V
w/ autorange 1000M/400M/40M/4M 2000MΩ/500V w/ autorange 2000M/400M/40M/4M 4000MΩ/1000V w/ autorange 4000M/400M/40M/4M Resolution : 4MΩ/1KΩ,
40MΩ/10KΩ 400MΩ/100KΩ, 4000MΩ/10MΩ Accuracy : 3%rdg+5Count <
1000MΩ
5%rdg+5Count > 1000MΩ Nominal Current : >1mA
■ Lo Ω
| Range |
Resolution |
Accuracy |
Short Ciruit
Current |
| 40.00Ω |
0.01Ω |
±2%rdg+2dgts |
>200mA |
■ AC
Voltage (50Hz to 400Hz)
| Range |
Resolution |
Accuracy |
Sensitivity |
Overload Protection |
| 1000V |
1V |
±2.0%+1dgts |
2V |
1000V rms |
Input impedance : 3MΩ
■ DC
Voltage
| Range |
Resolution |
Accuracy |
Sensitivity |
Overload Protection |
| 1000V |
1V
|
±1.0%+1dgts |
2V |
1000V rms |
Input impedance : 3MΩ
■ Resistance (Continuity<40Ω on the 9999Ω
range)
| Range |
Resolution |
Accuracy |
Overload Protection |
| 9999Ω |
1Ω |
1%rdg+2dgts |
1000V
rms |
GENERAL SPECIFICATIONS :
- Display : Dual display, 3-3/4 Digital readout with
analog bar indication.
- Sampling Rate : 2.5 times/sec
- Manual data Memory and Read : Memory capacity 9
sets
- Operating Temperature & Humidity : 0℃ to 50℃ below 80% RH
- Battery : 6 × 1.5V Size AA battery
- Fuse : 6mm x 32mm, 0.5/1000V
- Dimension : 235(L) x 116(W) x 54(H)mm
- Weight : 520g(with battery)
- Accessories : Test leads, 6pcs battery, Carrying
Case, Manual
|