UP
left
ÁÖ¹®Á¦ÀÛ
ÀüÀÚÀú¿ï
Á¤¹Ð Balance

°¢Á¾ °èÃø±â±â

°¢Á¾ ÃøÁ¤°ø±¸

»ê¾÷¿ëÀüÀÚÀú¿ï
»ó¾÷¿ëÀüÀÚÀú¿ï
Å©·¹ÀνºÄÉÀÏ
·Îµå¼¿
ÀεðÄÉÀÌÅÍ
ÇÁ¸°ÅÍ

ÃàÁß±â(À±Áß±â)

½ÅÀåÀÚµ¿ÃøÁ¤±â¹×
üÁß°è,°Ç°­º¸Á¶±â
¼öµ¿Àú¿ï¹×±âŸÀú¿ï
¼ö·Ïȸ»çº¸±â
³¯¾¾Á¤º¸
Àá°£ ½¬¾î °¡±â

NAVER.COM


¿©±æ¸¦ Ŭ¸¯Çϼ¼¿ä

  

 

 

 

 

Àü±â/ÀüÀÚ°èÃø±â50000 Counts TRMS Multimeter TES-2804(RS-232, RMS)

 

 

TES-2804

 

¡Ü50000 count Digital LCD with bar-graph
¡ÜTrue RMS ACV, ACA
¡ÜDMM talks with P.C. via RS-232 interface
¡ÜData logger function
¡ÜAUTO-Ranging on Volt, Ohm, Frequency
¡ÜCapacitance Measurement (500nF~500§Þ)
¡ÜAlso provides MAX/MIN, REL and data HOLD mode
¡ÜAuto power off 30 minutes

  

ELECTRICAL SPECIFICATIONS :
   
Accuracies are ±(...% of rdg + ...digits) at  23¡É±5¡É

 

 ¡á DC Voltage  (Autorange & Manual range)

Range

Resolution

Accuracy

Input

impedance

Overload protection

500mV

10µV

0.09% + 5d

¡Ö 10M§Ù

660Vrms

5V

0.1mV

50V

1mV

500V

10mV

600V

100mV

 

 ¡á AC Voltage  (Autorange & Manual range)

Range

Resolution

Accuracy

Input

impedance

Overload protection

 

 

0.9% + 20d

¡Ö 10M§Ù

660Vrms

5V

0.1mV

50V

1mV

500V

10mV

600V

100mV

 

 ¡á Frequency(Hz)  (Autorange)

Range

Resolution

Accuracy

Sensitivity

Overload protection

50Hz

0.001Hz

0% + 40d

200mV

660Vrms

500Hz

0.01Hz

5kHz

0.1Hz

50kHz

1Hz

500kHz

10Hz

400mV

10MHz

100Hz

1V

 

 ¡á Audible continuity

Range

Resolution

Open circuit

Voltage

Continuity

Beeper

Overload

protection

 

0.01§Ù

¡Ö3V

¡Â Approx. 40§Ù

660Vrms

 

 ¡á Resistance(§Ù) (Autorange & Manual range)

Range

Resolution

Accuracy

Open circuit

voltage

Overload

protection

500§Ù

0.01§Ù

0.3% + 10d

3V

660Vrms

5k§Ù

0.1§Ù

50k§Ù

1§Ù

500k§Ù

10§Ù

5M§Ù

100§Ù

0.9% + 20d

50M§Ù

1k§Ù

2% + 20d

 

 ¡á Diode test

Range

Resolution

Short circuit

Current

Open circuit

voltage

Overload

protection

 

0.1mV

0.8mA typical

3V

660Vrms

 

 ¡á Capacitance(F)

Range

Resolution

Accuracy

Sensitivity

500nF

100pF

0.9% + 20d

0.5A/660Vrms

5§Þ

1nF

50§Þ

10nF

500§Þ

100nF

2% + 20d

 

 ¡á AC Current (Manual range & Autorange)

Range

Resolution

Accuracy

Overload

protection

5000§Ë

0.1§Ë

0.9% + 20d

0.5A/600V

500mA

0.01mA

20A

1mA

20A/600V

 

 ¡á DC Current (Manual range & Autorange)

Range

Resolution

Accuracy

Overload

protection

5000§Ë

0.1§Ë

0.5% + 20d

0.5A/600V

500mA

0.01mA

20A

1mA

20A/600V

 

GENERAL SPECIFICATIONS :

  • Sampling Rate : 10 times/sec of Analog Bar-graph indication,
                              5.5 times/sec of digital display
  • Power source : 1pc 006p 9V 6F22 Battery
  • Auto Power Off : 30 minute approx. (LCD display "SLEEP")
  • Battery Life : 100hrs approx
  • Polarity : Automatic polarity "¦¡" indicates negative input
  • Operating Temp & Humidity : 0¡É to 40¡É(32¢µ to 104¢µ) below 80% RH
  • Storage Temp & Humidity : -10¡É to 60¡É(14¢µ to 140¢µ) below 70% RH
  • Dimensions : 205(L) x 90(W) x 46(H)mm
  • Weight : Approx. 420g
  • Accessories : Test leads, Battery and Instruction Manual,
                            RS-232 Cable, window S/W include

      °èÃø±âÀüü¸Þ´º 

                                welcome to sjscale@naver.com        
                            
Àú¿ï ¹× °èÃø±â±âÀÇ ¸ðµç °Í(½ÅÁ¤Á¤¹Ð±â°è) 
            
            (Tel:055-237-5300~2,FaX:055-237-5007)