Àü±â/ÀüÀÚ°èÃø±âLCR MultimeterTES-2712

 

 

TES-2712

 

¡Ü3-1/2 (3200 COUNTS) Digital LCD with Bar-graph
¡ÜAUTO-Ranging on Volt, Ohm, Current measurement
¡ÜAUTO-power off
¡ÜProvides data HOLD mode
¡ÜOhms, Diode / Audible continuity and Capacitance input Overload protection to 500Vrms
¡Ü20A/380V high energy fuse protection on 20A AC/DC
¡ÜFlip-up stand

  

ELECTRICAL SPECIFICATIONS :
   
Accuracies are ±(...% of rdg + ...digits) at  23¡É±5¡É. below 80% RH.

 

 ¡á DC Voltage

Range

Resolution

Accuracy

Input

impedance

Overload

protection

200mV

0.1mV

0.5%rdg + 1dgt

10M§Ù

660Vrms

2V

1mV

750Vpp

20V

10mV

200V

100mV

600V

1V

0.5%rdg + 2dgt

 

 ¡á AC voltage  : 50Hz ~ 500Hz

Range

Resolution

Accuracy

Input

impedance

Overload

protection

200mV

0.1mV

1%rdg + 5dgt

10M§Ù

660Vrms

2V

1mV

750Vpp

20V

10mV

200V

100mV

600V

1V

1.2%rdg + 5dgt

 

 ¡á DC Current

Range

Resolution

Accuracy

Burden Voltage

Overload

protection

200§Ë

0.1§Ë

1%rdg + 1dgt

0.35V

0.5A/250V
Fast Blow
Fuse & Diode

2mA

1§Ë

20mA

10§Ë

200mA

100§Ë

20A

10mA

1.2%rdg + 3dgt

0.8V

20A/380V Fast Blow Fuse

 

 ¡á AC current  : 50Hz ~ 500Hz

Range

Resolution

Accuracy

Burden Voltage

Overload

protection

200§Ë

0.1§Ë

1.2%rdg + 3dgt

0.35V

0.5A/250V
Fast Blow
Fuse & Diode

2mA

1§Ë

20mA

10§Ë

200mA

100§Ë

20A

10mA

1.5%rdg + 3dgt

0.8V

20A/380V Fast Blow Fuse

 

 ¡á Inductance(the accuracy is based on when "Q" value is greater than 1)

Range

Resolution

Accuracy

Test frequency

20mH

10¥ìH

5%rdg + 10dgt

200Hz

200mH

100¥ìH

2H

1mH

20H

10mH

 

 ¡á Capacitance(F)

Range

Resolution

Accuracy

Test frequency

2000pF

1pF

3%rdg + 10dgt

200Hz

200nF

100pF

2¥ìF

1nF

20¥ìF

10nF

 

 ¡á Frequency(Hz)(Test Range 10Hz-20MHz Auto Range)

Range

Resolution

Accuracy

Max. Open Circuit Voltage

Overload

protection

2kHz

1Hz

0.5%rdg + 2dgt

1.5Vrms

660Vrms

20kHz

10Hz

200kHz

100Hz

2MHz

1kHz

10MHz

10kHz

3Vrms

 

 ¡á Resistance(§Ù)

Range

Resolution

Accuracy

Max.
Open circuit voltage

Overload

protection

200§Ù

0.1§Ù

0.8%rdg + 2dgt

3.2V

660Vrms

2K§Ù

1§Ù

0.5V

20K§Ù

10§Ù

200K§Ù

100§Ù

2M§Ù

1K§Ù

20M§Ù

10K§Ù

1.5%rdg + 3dgt

 

 ¡á Diode

Range

Resolution

Accuracy

Max.
Open Circuit Voltage

 

1mV

2%rdg + 2dgt

3.2V

Max. Test Current

Overload Protection

1.0mA

660Vrms

 ¡á Continuity

Range

Resolution

Max.
Open Circuit Voltage

Overload

protection

 

¡Â 20§Ù

3.2V

600Vrms

 

GENERAL SPECIFICATIONS :

  1. Display : 3-1/2 digital liquid crystal display (LCD),
                    maximum reading 3999 and Bar-graph indication
  2. Palarity : Automatic "-" negative polarity indication
  3. Overrange : "OL" appears on the display
  4. Sampling Rate : 2.5 times per second
  5. Power : 9-Volt battery, NEDA 1604, IEC6F22 or JIS006P
  6. Operating /Storage Temperature and Humidity :
                0¡É to 40¡É, 0-80% RH / -10¡É to 60¡É, 0-70% RH
  7. Dimensions : 180(L) x 82(W) x 38(H)mm
  8. Weight : 365g
  9. Accessories : Test Leads, Spare Fuse(0.5A/250V), Battery, Instruction manual