ELECTRICAL SPECIFICATIONS :
¡á DC Voltage (Autorange & Manual range)
Range |
Resolution |
Accuracy |
Input
impedance |
Overload
protection |
400mV |
0.1mV |
±(0.5%rdg+1dgt) |
¡Ã100M§Ù |
DC 1100V AC 800V |
4V |
1mV |
¡Ö11M§Ù |
40V |
10mV |
¡Ö 10M§Ù |
400V |
100mV |
1000V |
1V |
¡á DC Current (Manual range)
Range |
Resolution |
Accuracy |
Input
impedance |
Burden
voltage |
4mA |
1§Ë |
±(1%rdg+1dgt) |
0.5A/250V fuse |
0.45V |
40mA |
10§Ë |
400mA |
100§Ë |
0.65V |
20A |
10mA |
±(1.5%rdg+2dgt) |
20A/600V high energy
fuse |
1.3V |
¡á AC voltage (Autorange & Manual) True RMS
Range |
Resolution |
Accuracy |
Input
impedance |
Overload protection |
Frequency Response |
400mV |
0.1mV |
±(1.2%rdg+5dgt) |
¡Ã100M§Ù |
DC 1100V AC 800V |
50 ~ 60 Hz |
4V |
1mV |
¡Ö11M§Ù |
40 ~ 450 Hz |
40V |
10mV |
¡Ö 10M§Ù |
400V |
100mV |
750V |
1V |
±(1.5%rdg+5dgt) |
¡Ø 400mV only manual range
¡á AC Current(Manual range) True RMS
Range |
Resolution |
Accuracy |
Input
impedance |
Burden
Voltage |
Frequency
Response |
4mA |
1§Ë |
±(1.5%rdg+5dgt) |
0.5A/250V fuse |
0.45V |
40Hz to 500Hz |
40mA |
10§Ë |
400mA |
100§Ë |
0.65V |
20A |
10mA |
±(2%rdg+5dgt) |
20A/600V high energy
fuse |
1.3V |
¡Ø Conversion type : AC coupled, TRMS measurement
¡á Addition Crest Factor Errors(non-sinecure)ACA/ACV
Crest
Factor |
Error(% of
reading) |
1-3 |
1% |
3-5 |
4.5% |
¡Ø [For frequencies at 50/60Hz, slow AC filter specified for sinecurve
input only.]
¡Ø Response time : 5 seconds max, to rated accuracy in the selected range
¡á Frequency(Hz) (Autoranging)
Range |
Resolution |
Accuracy |
Sensitivity |
100Hz |
0.01Hz |
±(0.1%rdg + 2dgts) |
100mV/1V/10V |
1kHz |
0.1Hz |
10kHz |
1kHz |
100kHz |
10Hz |
500kHz |
100Hz |
¡á Resistance(§Ù) (Autorange & Manual range)
Range |
Resolution |
Accuracy |
Open Circuit
Voltage |
Overload protection |
400§Ù |
100m§Ù |
±(0.75%rdg+3dgt) |
¡Ã0.5VDC |
600Vrms |
4k§Ù |
1§Ù |
40k§Ù |
10§Ù |
400k§Ù |
100§Ù |
4M§Ù |
1K§Ù |
40M§Ù |
10K§Ù |
±(1.5%rdg+5dgt) |
¡á Audible Continuity
Range |
Open Circuit
Voltage |
Continuity
Beeper |
Overload
protection |
|
¡Â0.5V |
¡ÂApprox.40§Ù |
600Vrms |
¡á Diode Test
Range |
Resolution |
Short Circui t
Current |
Accuracy |
Open
Circuit Voltage |
Overload protection |
|
1mV |
0.8mA typical |
±(1%rdg + 2dgts) |
3V |
600Vrms |
¡á ADP
Function |
Input |
Resolution |
Accuracy |
Overload
protection |
ADP |
400mVDC Full Scale |
1 Count/0.1mV |
±0.5%rdg + 2LSD |
600Vrms |
¡á Capacitance : (Autoranging & Manual range)
Range |
Resolution |
Accuracy |
4nF |
1pF |
±(1.5%rdg+20dgt) |
40nF |
10pF |
400nF |
100pF |
±(1.5%rdg+10dgt) |
4¥ìF |
1nF |
40¥ìF |
10nF |
GENERAL SPECIFICATIONS :
- Range Selection :
All ranges are selected by a single range switch operation
- Low Battery Indication :
The is
displayed when the battery voltage drops below the operating voltage
- Sampling Rate : 20
times/sec of Bargraph indication
2 times/sec of
digital display
- Power : 2pcs of "AA" 1.5V
Battery
- Battery Life : 400hr
approx.
- Auto power off time :
Approx. 30 minutes
- Operating Temperature and Humidity : 0¡É to 40¡É(32¢µ to 104¢µ) below
80% RH.
- Storage Temperature and Humidity : -10¡É to 60¡É(14¢µ to 140¢µ) below
70% RH.
- Dimensions, Weight :
184(L) x 82(W) x 42(H)mm, Approx. 375g
- Accessories : Test Leads,
Spare Fuse(0.5A/250V), Battery, Instruction manual
|