Àü±â/ÀüÀÚ°èÃø±âLCR MultimeterTES-2360

 

 

TES-2360

 

¡ÜAuto-power off 3-3/4 digit
¡ÜFrequency Count (Auto-Ranging)
¡Ü4000 count DMM with Peak Hold
¡ÜInductance, Capacitance and Temperature (diode type) checks

  

ELECTRICAL SPECIFICATIONS :
   
Accuracies are ±(...% of rdg + ...digits) at  23¡É±5¡É. below 80% RH.

 

 ¡á DC Voltage

Range

Resolution

Accuracy

Input

impedance

Overload

protection

400mV

0.1mV

0.5% + 1

10M§Ù

500V DC/AC

4V

1mV

1100VDC
800VAC

40V

10mV

400V

100mV

1000V

1V

 

 ¡á AC voltage  

Range

Resolution

Accuracy

Input

impedance

Overload

protection

400mV

0.1mV

1% + 3

10M§Ù

500V DC/AC

4V

1mV

1100VDC
800VAC

40V

10mV

400V

100mV

750V

1V

1.2% + 3

 

 

 ¡á AC Current

Range

Resolution

Accuracy

Burden Voltage

Overload

protection

400§Ë

0.1§Ë

1.2% + 3

0.5 Vmax

0.5A/250V Fast
Fuse & Diodes

40mA

10§Ë

400mA

100§Ë

10A

10mA

1.5% + 3

0.7 Vmax

 

 

 ¡á DC current  

Range

Resolution

Accuracy

Burden Voltage

Overload

protection

400§Ë

0.1§Ë

1% + 1

0.5 Vmax

0.5A/250V Fast
Fuse & Diodes

40mA

10§Ë

400mA

100§Ë

10A

10mA

1.2% + 1

0.7 Vmax

 

 

 ¡á Resistance(§Ù)

Range

Resolution

Accuracy

Max.
Open circuit voltage

Overload

protection

400§Ù

0.1§Ù

0.8% + 2

3.5V

500Vrms

4K§Ù

1§Ù

0.3V

40K§Ù

10§Ù

400K§Ù

100§Ù

4M§Ù

1K§Ù

40M§Ù

10K§Ù

1.5% + 2

 

 ¡á Diode

Range

Resolution

Accuracy

Max.
Test Current

Max.
Open Circuit Voltage

Overload

protection

 

1mV

2% + 1

1.5mA

3.5V

500Vrms

 

 

 ¡á Continuity

Range

Operating Resolution

Max. Open Circuit Voltage

Overload Protection

 

Continuity audible tone for
tested resistance below 100§Ù

3.5V

500Vrms

 

 ¡á Frequency(Hz)(Test Range 10Hz-4000kHz, Pluse width>2µs)(Auto Range)

Range

Resolution

Accuracy

Max.
Input Sensitivity

Overload

protection

4KHz

1Hz

0.5% + 1

1Vrms

350Vrms

40KHz

10Hz

400KHz

100Hz

4000KHz

1KHz

2Vrms

 

 ¡á Logic(¡ã¡å)

Range

input
Voltage

input
Impedance

Logic
thresholds

Min.Detectable
pulse width

Max. Input
frequency

LCD Display
number

Overload
protection

Logic
(¡ã¡å)

5VDC

120K§Ù

1

2.4 ± 0.3V, "¡ã" Dispaly

25ns

20MHz

OL.

350Vrms

0

0.7 + 0.3V, "¡å" Dispaly

(with beeper switch)

  

 ¡á Capacitance(F)

Range

Resolution

Accuracy

Test frequency

4nF

1pF

5% + 10

200Hz

40nF

10pF

400nF

100pF

4¥ìF

1nF

40¥ìF

10nF

 

 ¡á Inductance(H)

Range

Resolution

Accuracy

Test condition

4mH

1¥ìH

5% + 10

200Hz

40mH

10¥ìH

400mH

100¥ìH

4H

1mH

40H

10mH

 

 ¡á TEMPERATURE

Optional probe : Diode type sensor(TP-D05)

Range

Resolution

Test Range

Accuracy

¡É

0.1¡É

-40¡É to 150¡É

±2¡É

¢µ

0.1¢µ

-40¢µ to 302¢µ

±3¡É

 

GENERAL SPECIFICATIONS :

  • Power Source : 006P DC9V 1pc
  • Size & Weight : 187(L) × 88(W) × 37(H)mm & 374g
  • Accessories : Test Leads, Spare Fuse(0.5A/250V), Battery, Operating Instructionl

      °èÃø±âÀüü¸Þ´º 

                                welcome to sjscale@naver.com        
                            
Àú¿ï ¹× °èÃø±â±âÀÇ ¸ðµç °Í(½ÅÁ¤Á¤¹Ð±â°è) 
            
            (Tel:055-237-5300~2,FaX:055-237-5007)