UP
left
ÁÖ¹®Á¦ÀÛ
ÀüÀÚÀú¿ï
Á¤¹Ð Balance

°¢Á¾ °èÃø±â±â

°¢Á¾ ÃøÁ¤°ø±¸

»ê¾÷¿ëÀüÀÚÀú¿ï
»ó¾÷¿ëÀüÀÚÀú¿ï
Å©·¹ÀνºÄÉÀÏ
·Îµå¼¿
ÀεðÄÉÀÌÅÍ
ÇÁ¸°ÅÍ

ÃàÁß±â(À±Áß±â)

½ÅÀåÀÚµ¿ÃøÁ¤±â¹×
üÁß°è,°Ç°­º¸Á¶±â
¼öµ¿Àú¿ï¹×±âŸÀú¿ï
¼ö·Ïȸ»çº¸±â
³¯¾¾Á¤º¸
Àá°£ ½¬¾î °¡±â

NAVER.COM


¿©±æ¸¦ Ŭ¸¯Çϼ¼¿ä

  

 

 

 

 

Àü±â/ÀüÀÚ°èÃø±âClamp-on Ground TesterProva-5600/5601/5637

 

 

Prova-5600/5601/5637

 

¡ÜNon-Contact Ground Resistance Measurement
¡ÜNo Auxiliary Electrode Needed
¡Ü
0.025 – 1500 Ohm
¡Ü
Jaw Diameter ¥Õ 23 mm (5600,5601)
¡Ü
Jaw Diameter ¥Õ 35 mm(5637)
¡Ü
0.2mA– 30A(5600,5601)0.2mA– 35A(5637),True RMS
¡Ü
116 Sets of Memory(5601,5637)
¡Ü
Programmable Hi and Lo Alarm(5601,5637)
¡Ü
Programmable Data Logging (5601,5637)

  

ELECTRICAL SPECIFICATIONS : (23¡É±5¡É)

* Ground Resistance (Autorange) :

Range

Rssolution

Accuracy of Reading1

0.025-0.250§Ù

0.002§Ù

±1.5%±0.05§Ù

0.250-9.999§Ù

0.02§Ù

±1.5%±0.1§Ù

10.00-99.99§Ù

0.04§Ù

±2.0%±0.3§Ù

100.0-199.9§Ù

0.4§Ù

±3.0%±1.0§Ù

200.0-400.0§Ù

2§Ù

±5.0%±5§Ù

400.0-600.0§Ù

5§Ù

±10%±10§Ù

600.0-1500§Ù

20§Ù

±20% (Approx.)

1 Loop resistance noninductive, external field < 50 A/m, external electrical field < 1 V/m,

  conductor centered.

2 Resistance Measurement Frequency : 1.667KHz Continuity

 

* Continuity

Beep if resistance < 40.00§Ù(Approximately)

 

* Ground/Leakage Current(Autorange, 50/60 Hz, True RMS, Crest Factor < 3.0)

Range

Resolution

Accuracy of Reading

0.200-1.000 mA

0.001mA

±2.5%±0.05mA

1.00-10.00mA

0.01mA

±2.5%±0.05mA

10.0-100.0mA

0.1mA

±2.0%±0.3mA

100-1000mA

1mA

±2.0%±3mA

 

* Ground/Leakage Current (50/60 Hz, True RMS, Crest Factor < 3.0)

Range

Resolution

Accuracy of Reading

0.20-30.00A

0.01A

±2.0%±0.03A

Max. Current Protection : 100A continuous, 200A(<60sec) 50/60 Hz

 

 GENERAL SPECIFICATIONS :

  • Conductor Size : 23 mm approx.
  • Battery Type : 9V Alkaline
  • Display Type : 4 digits 9999 counts LCD
  • Range Selection : Auto
  • Overload Indication : OL
  • Power Consumption : 40mA
  • Low Battery Indication :
  • Sampling Time : 0.4 seconds
  • Operating Temperature : 4¡É to 50¡É
  • Operating Humidity : Less than 85% RH
  • Storage Temperature : -20¡É to 60¡É
  • Storage Humidity : Less than 75% RH
  • Dimension : 257mm(L) x 100mm(W) x 47mm(H)
  • Weight : 640g
  • Accessories : Resistance Calibration Plate x 1/ 9V Battery (Installed) x 1
                           Users Manual x 1/ Rugged Carrying Case x 1