UP
left
ÁÖ¹®Á¦ÀÛ
ÀüÀÚÀú¿ï
Á¤¹Ð Balance

°¢Á¾ °èÃø±â±â

°¢Á¾ ÃøÁ¤°ø±¸

»ê¾÷¿ëÀüÀÚÀú¿ï
»ó¾÷¿ëÀüÀÚÀú¿ï
Å©·¹ÀνºÄÉÀÏ
·Îµå¼¿
ÀεðÄÉÀÌÅÍ
ÇÁ¸°ÅÍ

ÃàÁß±â(À±Áß±â)

½ÅÀåÀÚµ¿ÃøÁ¤±â¹×
üÁß°è,°Ç°­º¸Á¶±â
¼öµ¿Àú¿ï¹×±âŸÀú¿ï
¼ö·Ïȸ»çº¸±â
³¯¾¾Á¤º¸
Àá°£ ½¬¾î °¡±â

NAVER.COM


¿©±æ¸¦ Ŭ¸¯Çϼ¼¿ä

  

 

 

 

 

Àü±â/ÀüÀÚ°èÃø±âAC Digital Clamp Meter(1000A)TES-3070

 

 

TES-3070

 

¡Ü 3-3/4 Digital LCD
¡ÜData Hold mode
¡ÜPeak Hold

  

A : General Measurement

 

 ¡á AC Voltage

Range

Resolution

Accuracy

Input

impedance

Overload

protection

Frequency Response

400V

0.1V

±(1.2%rdg + 5dgts)

1M§Ù

660Vrms

40~450Hz

600V

1V

 

 ¡á DC Voltage

Range

Resolution

Accuracy

Input

impedance

Overload

protection

Frequency Response

600V

1V

±(0.75%rdg + 5dgts)

1M§Ù

660Vrms

40~450Hz

 

 

 ¡á Frequency(Hz) (Autorange for Current & Voltage)

Range

Resolution

Accuracy

Sensitivity

Overload Protection

4KHz

1Hz

±(0.5%rdg + 5dgts)

1A/1V

800A
660Vrms

20KHz

10Hz

15A/1V

 

 ¡á AC Current

Range

Resolution

Accuracy

Overload

protection

Frequency Response

40A

0.01A

±(2%rdg + 5dgts)

800A

40~450Hz

400A

0.1A

600A

1A

 

 

 ¡á Resistance(§Ù)

Range

Resolution

Accuracy

Open circuit

Voltage

Overload

protection

4K§Ù

0.001K§Ù

±(1%rdg + 5dgts)

¡Â0.5 VDC

660Vrms

 

 ¡á Diode test / Audible continuty

Range

Resolution

Accuracy

Overload Protection

0.001V

±(1%rdg + 2dgts)

660Vrms

Range

Continuity beeper

Open Circuit Voltage

Overload Protection

¡Â40§Ù

¡Â0.5V

660Vrms

 

      B : Peak Hold Measurement

 ¡á AC Voltage

Range

Resolution

Accuracy

Input

impedance

Overload

protection

Frequency Response

400V

0.1V

±(1.2%rdg + 10dgts)

1M§Ù

660Vrms

40~450Hz

600V

1V

 

 ¡á AC Current

Range

Resolution

Accuracy

Overload

protection

Frequency Response

40A

0.01A

±(2%rdg + 10dgts)

800A

40~450Hz

400A

0.1A

600A

1A

 

 GENERAL SPECIFICATIONS :

 

  • Numerical Display : 3-3/4 digit liquid crystal display (LCD) maximum reading 3999
  • Range Selection : All ranges are selected by a single range switch
  • Over Range Indication : LCD will show an "OL"
  • Low Battery Indication : The is displayed when the battery voltage drops
                                            below the operating voltage
  • Sampling Rate : 2 times/sec
  • Power Source : one 006p 9V or IEC 6F22 or NEDA 1604 Battery
  • Battery Life : 300hr approx.
  • Polarity : Automatic polarity " - " display for negative input
  • Auto power off time : Approx. 30 minutes
  • Operating Temp/Humidity : 0¡É to 40¡É(32¢µ to 104¢µ) below 80%RH
  • Dimensions : 228(L) x 76(W) x 39(H)mm
  • Weight : Approx. 465g
  • Jaw Opening Diamete : Cables ¥Õ40mm
  • Accessories : Battery, Manual, Test Leads, Carry Case

      °èÃø±âÀüü¸Þ´º 

                                welcome to sjscale@naver.com        
                            
Àú¿ï ¹× °èÃø±â±âÀÇ ¸ðµç °Í(½ÅÁ¤Á¤¹Ð±â°è) 
            
            (Tel:055-237-5300~2,FaX:055-237-5007)