ELECTRICAL SPECIFICATIONS :
(23¡É±5¡É)
¡á AC + DC Watt
Range |
Resolution |
Accuracy |
Remark |
AC 40KW |
10W |
±1.5% + 3dgts |
0-250V, 0-400A,PF 0-1 50/60Hz,
Vpeak<360V |
AC 240KW |
100W |
±1.5% + 3dgts |
0-600V, 0-400A,PF 0-1 50/60Hz,
Vpeak<850V |
AC 40KW |
10W |
±2.5% + 3dgts |
0-250V, 0-400A,PF 0-1 40-1Hz,
Vpeak<360V |
AC 240KW |
100W |
±2.5% + 3dgts |
0-600V, 0-400A,PF 0-1 40-1Hz,
Vpeak<360V |
DC40KW |
10W |
±1.5% + 3dgts |
0-250V, 0-400A,PF 0-1
|
DC240KW |
100W |
±1.5% + 3dgts |
0-600V, 0-400A,PF
0-1 |
¡á DC Current
Range |
Resolution |
Accuracy |
Overload Protection |
400A |
100mA |
±1.5%+3dgts |
DC 600A |
¡á AC Current (True RMS, Crest
Factor < 4)
Range |
Resolution |
Accuracy |
Overload Protection |
50/60Hz |
40 - 1KHz |
400A |
100mA |
±1.5%+3dgts |
±2.5%+4dgts |
AC 600A |
¡á DC Voltage : (Input Impedance :
10M§Ù)
Range |
Resolution |
Accuracy |
Overload Protection |
400V |
0.1V |
±1.0% + 2dgts |
DC
800A |
¡á AC Voltage : (Input Impedance :
10M§Ù, True RMS, Crest Factor < 4)
Range |
Resolution |
Accuracy |
Overload Protection |
50/60Hz |
40 - 1KHz |
600V |
1V |
±1.5% + 2dgts |
±2.0% + 4dgts |
AC
800A |
¡á Frequency (Auto range) :
Range(hz) |
Resolution(Hz) |
Accuracy |
Sensitivity |
Overload Protection |
100-1000K |
0.01-100 |
±0.8%±2dgts |
10 V |
AC 600V |
GENERAL SPECIFICATIONS :
- Conductor Size : 23mm max. (approx.)
- Battery : two 1.5V SUM-3
- Display : 3-3/4 LCD with 40 seg. bargraph
- Range Selection : manual
- Overload Indication : left most digit blinks
- Power Consumption : 10mA (approx)
- Low battery Indication :
- Auto-Power-Off : 30 minutes after power-off
- Sampling Time : 2 times/sec.
(display)
20 times/sec. (bargraph)
- Operating Temperature : -10¡É to 50¡É
- Operating Humidity : less than 85% relative
- Storage Temperature : -20¡É to 60¡É
- Storage Humidity : less than 75% relative
- Dimension : 183mm (L) x 61.3mm (W) x 35.6mm (H)
- Weight : 190g (battery Included)
- Accessories : Carrying Bag, Users Manual, 1.5V battery, Test
Leads
|