ELECTRICAL SPECIFICATIONS : (23¡É±5¡É)
¡á DC Current :
Range |
Resolution |
Accuracy |
Overload Protection |
40A |
10mA |
±1.5%±2dgts |
DC 400A |
0-150A |
100mA |
±1.5%±2dgts |
DC 400A |
150-200A |
100mA |
±2.2%±2dgts |
DC 400A |
¡á AC Current :
Range |
Resolution |
Accuracy |
Overload Protection |
50/60Hz |
40 - 1KHz |
40A |
10mA |
±1.5%±3dgts |
±2.0%±4dgts |
AC 400A |
0-150A |
100mA |
±1.5%±3dgts |
±2.0%±4dgts |
AC 400A |
150-200A |
100mA |
±2.2%±3dgts |
±2.5%±4dgts |
AC 400A |
¡á DC Voltage : (Overload Protection
: 600V)
Range |
Resolution |
Accuracy |
Input Impedance |
400 mV |
0.1 mV |
±1.5%±3dgts |
10M§Ù |
4V |
1mV |
±1.5%±3dgts |
5M§Ù |
40V |
10mV |
±1.5%±3dgts |
5M§Ù |
400V |
100mV |
±1.5%±3dgts |
5M§Ù |
600V |
1V |
±1.5%±3dgts |
5M§Ù |
¡á Continuity : (Open Voltage 0.4V,
Overload Protection AC600V)
Range |
Resolution |
Accuracy |
Beeping |
40-400§Ù |
0.1§Ù |
±1.0%±2dgts |
<40.0§Ù(approx.) |
¡á AC Voltage : (Input Impedance
5M§Ù)
Range |
Resolution |
Accuracy |
Overload Protection |
50/60Hz |
40 - 1KHz |
0.01-4V |
1mV |
±1.5%±5dgts |
±2.0%±5dgts |
AC 800V |
40V |
10mV |
±1.5%±5dgts |
±2.0%±5dgts |
AC 800V |
400V |
100mV |
±1.5%±5dgts |
±2.0%±5dgts |
AC 800V |
600V |
1V |
±1.5%±5dgts |
±2.0%±5dgts |
AC 800V |
1
400mV range is not designed for AC measurement.
¡á Resistance(§Ù) : (Open Voltage
0.4V)
Range |
Resolution |
Accuracy |
Overload Protection |
400§Ù |
0.1§Ù |
±1.5%±2dgts |
AC 600V |
4K§Ù |
1§Ù |
±1.5%±2dgts |
AC 600V |
40K§Ù |
10§Ù |
±1.5%±2dgts |
AC 600V |
400K§Ù |
100§Ù |
±1.5%±2dgts |
AC 600V |
4M§Ù |
1K§Ù |
±1.5%±2dgts |
AC 600V |
40M§Ù |
10K§Ù |
±1.5%±2dgts |
AC 600V |
¡á Frequency(CM-02, Auto,
Sensitivity selected by pressing RANGE Button) :
Range(Hz) |
Resolution(Hz) |
Accuracy |
Sensitivity |
O.L Protection |
100-100K |
0.01-100 |
±0.5%±2dgts |
0.01 / 0.1 / 1V |
AC 600V |
¡á RPM (CM-04 with Option RPM
Adaptor) :
Range(RPM) |
Resolution(RPM) |
Accuracy |
Overload Protection
|
0-9999 |
1 |
±0.5%±2dgts |
AC 600V |
¡á TEMPERATURE (K Type Thermal
Couple with Adapter, ¡É or ¢µ) :
Range |
Resolution |
Accuracy |
Overload Protection |
-40 - 0¡É |
0.1¡É |
±2.0% ± 2¡É |
AC 600V |
0 - 400¡É |
0.1¡É |
±0.5% ± 2¡É |
AC 600V |
400 - 1000¡É |
1¡É |
±0.5% ± 2¡É |
AC 600V |
-40 - 0¢µ |
0.1¢µ |
±2.0% ± 4¢µ |
AC 600V |
0 - 400¢µ |
0.1¢µ |
±0.5% ± 4¢µ |
AC 600V |
400 - 1800¢µ |
1¢µ |
±0.5% ± 4¢µ |
AC 600V |
¡á CAPACITANCE :
Range |
Resolution |
Accuracy |
Overload Protection |
4nF |
1pF |
±5.0%±0.2nF |
AC 600V |
40nF |
10pF |
±5.0%±0.2nF |
AC 600V |
400nF |
0.1nF |
±3.0%±0.2nF |
AC 600V |
4uF |
1nF |
±3.0%±0.02uF |
AC 600V |
40uF |
10nF |
±3.0%±0.02uF |
AC 600V |
GENERAL SPECIFICATIONS :
Conductor Size : 23mm max.
(approx.)
Battery : two 1.5V SUM-3
Display : 3-3/4 LCD with 40 seg.
bargraph
Range Selection : manual
Overload Indication : left most digit
blinks
Sampling Time : 2 times/sec.
(display) 20 times/sec.
(bargraph)
Operating Temperature : -10¡É to
50¡É
Operating Humidity : less than 85%
relative
Storage Temperature : -20¡É to
60¡É
Storage Humidity : less than 75%
relative
Dimension : 183mm (L) x 63.6mm (W) x
35.6mm (H)
Weight : 190g (battery
Included)
Accessories : Adaptor(for Capacitance and
K-type Thermal Couple),Carry case,
Manual, Battery, Test Leads, k-type
Thermal Couple(TP-K01)
Option Accessory : RPM adaptor(only
CM-04) |