ELECTRICAL SPECIFICATIONS : (23¡É±5¡É)
¡á DC Current :
Range |
Resolution |
Accuracy |
Overload Protection |
40A |
10mA |
±1.0%±2dgts |
DC 400A |
0-150A |
100mA |
±1.0%±2dgts |
DC 400A |
150-200A |
100mA |
±2.2%±2dgts |
DC 400A |
¡á AC Current :
Range |
Resolution |
Accuracy |
Overload Protection |
50/60Hz |
40 - 1KHz |
40A |
10mA |
±1.0%±3dgts |
±1.5%±4dgts |
AC 400A |
0-150A |
100mA |
±1.0%±3dgts |
±1.5%±4dgts |
AC 400A |
150-200A |
100mA |
±2.2%±3dgts |
±2.5%±4dgts |
AC 400A |
¡á DC Voltage : (Input Impedance :
10M§Ù)
Range |
Resolution |
Accuracy |
Overload Protection |
400V |
0.1V |
±1.0%±2dgts |
DC 1000V |
¡á AC Voltage : (Input Impedance :
10M§Ù)
Range |
Resolution |
Accuracy |
Overload Protection |
50/60Hz |
40 - 1KHz |
400V |
0.1V |
±1.5%±2dgts |
±2.0%±4dgts |
AC 800V |
¡á Resistance(§Ù) and Continuity :
(Open Voltage 0.4V)
Range |
Resolution |
Accuracy |
Beeping |
OL Protection |
40-400§Ù |
0.1§Ù |
±1.0%±2dgts |
<40.0§Ù(approx.) |
AC 600V |
¡á Frequency (auto
range)
Range(Hz) |
Resolution(Hz) |
Accuracy |
Sensitivity |
Overload Protection |
100-1000K |
0.01-100 |
±0.5%±2dgts |
10 V |
AC 600V |
GENERAL SPECIFICATIONS :
Conductor Size : 23mm max.
(approx.)
Battery : two 1.5V SUM-3
Display : 3-3/4 LCD with 40 seg.
bargraph
Range Selection : manual
Overload Indication : left most digit
blinks
Power Consumption : 10mA
(approx)
Low battery Indication :
Sampling Time : 2 times/sec.
(display) 20 times/sec.
(bargraph)
Operating Temperature : -10¡É to
50¡É
Operating Humidity : less than 85%
relative
Altitude : up to 2000M
Storage Temperature : -20¡É to
60¡É
Storage Humidity : less than 75%
relative
Dimension : 183mm (L) x 63.6mm (W) x
35.6mm (H)
Weight : 190g (battery
Included)
Accessories : Carrying Bag, Users Manual,
1.5V battery, Test Leads |