ȯ°æ°ü·Ã ÃøÁ¤±â±â¼öÁú°ü·Ã±â±âŹµµ°è2100AN,2100N,2100P

 

 

2100AN

2100N

2100P

2100AN,2100N,2100P

 

 2100AN °ú 2100NÀÇ Æ¯Â¡
¡Ü½ÇÇè½Ç, »ê¾÷Q.C¿ë, ¿¬±¸¸ñÀûµîÀÇ »ç¿ëºÐ¾ß°¡ ±¤¹üÀ§ÇÏ°í 3 Á¾·ù Æǵ¶¸ðµå(NTU,NEPHELOS,EBS)¸¦
   ÀÌ¿ëÇÏ¿© ¼ø¼ö¿¡¼­ Æó¼ö±îÁö ±¤¹üÀ§ÇÑ ÃøÁ¤¹üÀ§¸¦ ¼ö ÀÖÀ½.
¡Ü´ÙÁß µðÅØÅ͸¦ ä¿ëÇÏ¿© RATIO, NON-RATIO, SINGLE 90 µðÅØÅÍ ÃøÁ¤¸ðµå¸¦ ÇѹøÀÇ Å°·Î Á¶ÀÛÇÒ ¼ö
    ÀÖÀ½. (2100AN)
¡Ü½Ã±×³¯ ¿¡¹ö¸®Áö ±â´ÉÀ» ä¿ëÇÏ¿© ½ÇÁ¦ º£À̽º¶óÀο¡ ÀÇ°ÅÇÑ ÃøÁ¤À» ÇÒ ¼ö ÀÖµµ·Ï ÀâÀ½°ú Æĵ¿À»
   ÃÖ¼ÒÈ­  ÇÔ.
¡Ü¸¶ÀÌÅ©·Î ÇÁ·Î¼¼¼­¿¡ ³»ÀåµÈ ÇÁ·Î±×·¥¿¡ ÀÇÇÑ ÀÚµ¿ Ä̸®ºê·¹ÀÌ¼Ç ¼öÇà.
¡Ü¼±¸íÇÏ°í ¹àÀº LED Display
¡ÜÀÚ°¡Áø´Ü ±â´ÉÀÌ ³»ÀåµÇ¾î ±â±âÀÇ ÀÌ»óÀ¯¹«¸¦ ½±°Ô ÆÇ´ÜÇÏ¿©  Á¤¹ÐÇÑ ÃøÁ¤°ªÀ» ¾òÀ»¼ö ÀÖÀ½.
¡Ü¿ø¹® Overview
Model 2100AN and 2100N Laboratory Turbidimeters measure turbidity in either ratio or non-ratio mode. Light from a tungsten-filament lamp is focused and passed through the sample.
The 90-degree scatter detector receives light scattered by particles.
Transmitted and forward scatter detectors receive light that passes through the sample.
A back scatter detector in the 2100AN Model (shown here) measures light scattered back toward the light source.

Ratio and non-ratio measurement modes are selected using the ratio key located on the instrument keyboard. With ratio toggled off, turbidity is measured using only the single 90-degree detector. Benefits of the ratio mode include long-term calibration stability, wide measurement range with excellent linearity, and the ability to measure turbidity in the presence of color.

2100P¿Í Æ÷ÄÏ¿ë Źµµ°èÀÇ Æ¯Â¡
¡Ü½ÇÇè½Ç ¹× ÈÞ´ë°â¿ë(2100P)°ú ÈÞ´ëÀü¿ë(Æ÷ÄÏ¿ë)À¸·Î »ç¿ë¸ñÀû¿¡ µû¶ó ¼±ÅÃÇÒ¼ö ÀÖÀ½.
¡Ü¸¶ÀÌÅ©·ÎÇÁ·Î¼¼¼­¿¡ ³»ÀåµÈ ÇÁ·Î±×·¥¿¡ µû¶ó ÀÚµ¿ Ä̸®ºê·¹ÀÌ¼Ç ¼öÇà
¡Ü½ÇÇè½Ç¿¡¼­ 1ȸ Ä̸®ºê·¹À̼ÇÀ¸·Î ÇöÀå¿¡¼­ ¿¬¼Ó ÃøÁ¤»ç¿ë °¡´É
¡ÜÁ¤µµ ³ôÀº ÃøÁ¤°ªÀ» ¾òÀ»¼ö ÀÖÀ½ .
¡ÜÁ¤¼ö, Æó¼ö¿¡ ±¤¹üÀ§ÇÏ°Ô ÀÌ¿ëÇÒ ¼ö ÀÖÀ½.
  Lab Quality Results in a Portable Unit

  • Range: 0 to 1000 NTU
  • Selectable signal averaging mode compensates for fluctuations in readings caused by movement of large particles in the light path
  • Pre-programmed calibration procedure, with microprocessor-controlled adjustment of calibration curve. No potentiometers to adjust
  • Electronic zeroing: compensates for electronic and optical offsets. No manual adjustments are required
  • Direct digital readout in NTU
  • Meets or exceeds USEPA method 180.1 criteria
  • Comes with six sample cells, 4 sealed vials of StablCal Primary Standards (<0.1, 20, 100, and 800 NTU), Secondary Gelex Standards, silicone oil and oiling cloth

  

 2100AN ¹× 2100N, 2100P»ç¾ç

±¸ºÐ

2100AN

2100N

2100p

ÃøÁ¤¹æ½Ä

Nephelometric signal (90° ratioed to transmitted, forward scattered and back scattered signals; or nephelometric signal at 90°only

2100AN°ú µ¿ÀÏ

Nephelometric Ratio

ÀÛµ¿¹æ½Ä

Manual or Auto Range Selection
Signal Averaging On/Off
Ratioing On/Off

2100AN°ú µ¿ÀÏ

ÀÚµ¿¶Ç´Â ¼öµ¿¼±ÅÃ
Ratio °¡´ÉON/OFF

ÃøÁ¤¸ðµå

¼±ÅÃ:NTUs,EBCs,Nephelos,
       ABS, %T, Color

¼±ÅÃ:NTUs,EBCs,Nephelos

NTU

 ÃøÁ¤¹üÀ§

NTU ¸ðµå

RATIO ON: Manual 0-0.999, 0-9.99, 0-99.9, 0-10,000
Auto 0-10,000
RATIO OFF: 0-40.0

RATIO ON: Manual 0-0.999, 0-9.99, 0-99.9, 0-4,000
Auto 0-4,000
RATIO OFF: 0-40.0

0-1000 NTU with automatic decimal point placement or manual range selection of 0-9.99, 0-99.9 and 0-1000 NTU selection

Nephelo¸ðµå

RATIO ON: Manual 0-9.99, 0-99.9 and 0-67,000;
Auto 0-67,000
RATIO OFF: 0-268

RATIO ON: Manual 0-9.99, 0-99.9, 0-26,800;
Auto 0-26,800
RATIO OFF: 0-268

-

EBC ¸ðµå

RATIO ON: Manual 0-0.999, 0-9.99, 0-99.9, 0-2,450;
Auto 0-2,450
RATIO OFF: 0-9.8

RATIO ON: Manual 0-0.999, 0-9.99, 0-99.9, 0-980;
Auto 0-980
RATIO OFF: 0-9.8

-

Absorbance

Manual: 0.0 ABS to 0.999 ABS,
0 ABS to 2.00 ABS
Auto: 0.0 ABS to 3.00 ABS

-

-

Transmmitance

Range 0.0 to 200 %T
Resolution: 0.1 %T

-

-

»öµµ(455nm)

Range: 0 to 500 CU
Resolution: 1 CU

-

-

Á¤¹Ðµµ

Źµµ

Æǵ¶Ä¡ÀÇ ±2%(0~1000NTU)/0.01NTU
Æǵ¶Ä¡ÀÇ ±5%(1000~4000NTU) Æǵ¶Ä¡ÀÇ ±10%(4000~10,000NTU)

Æǵ¶Ä¡ÀÇ ±2%(0~1000NTU)/0.01NTU
Æǵ¶Ä¡ÀÇ ±5%(1000~4000NTU)

Æǵ¶Ä¡ÀÇ ±2%(0~500NTU)
Æǵ¶Ä¡ÀÇ ±3%(500~1000NTU)

»öµµ
(Color measurement*)

±2 CU from 0-30
(calibrated at 15 CU)
±5 CU from 0-500
(calibrated at 500 CU)

-

-

ABS* (photometric linearity)
Èí±¤µµ
(±¤µµÁ÷¼±¼º)

±0.005 ABS from 0-1 ABS at 455 nm
* Flow cell required to achieve    cited specifications.

-

-

%T* (photometric linearity)
Åõ±¤µµ
(±¤µµÁ÷¼±¼º)

±1.2 %T from 0 to 100 %T
at 455 nm
* Flow cell required to achieve    cited specifications.

-

-

ºÐÇØ´ÉResolution

0.001 on lowest range

2100AN°ú µ¿ÀÏ

ÃÖ¼Ò ¹üÀ§¿¡¼­ 0.01

ÀçÇö¼º

Æǵ¶Ä¡ÀÇ ±1% ¶Ç´Â ±0.01NTU

2100AN°ú µ¿ÀÏ

Æǵ¶Ä¡ÀÇ ±1% ¶Ç´Â
°¡Àå Å«¹üÀ§¿¡¼­ 0.01NTU

°¨µµ

½Ã±×³¯Æò±Õ ON½Ã 6.8ÃÊ,
½Ã±×³¯Æò±Õ OFF½Ã 14ÃÊ

2100AN°ú µ¿ÀÏ

constant Æǵ¶¸ðµå¿¡¼­(signal avg. off)6ÃÊ

ÃøÁ¤Ä¡Ç¥½Ã

5ÀÚ¸® LED

4ÀÚ¸® LED

4ÀÚ¸® LED

»ùÇ÷®

20 mL (0.7 oz)

30 mL (1 oz)

15§¢

·¥ÇÁ

ÅÖ½ºÅÙ ·¥ÇÁ(¼ö¸í8800½Ã°£)

2100AN°ú µ¿ÀÏ

ÅÖ½ºÅÙ ·¥ÇÁ(¼ö¸í100,000ȸÆǵ¶)

ÀÛµ¿¿Âµµ

0~40¡É((32 to 104¢µ)

2100AN°ú µ¿ÀÏ

0~50¡É

º¸°ü¿Âµµ

-40~60¡É((­40 to 140 ¢µ)

2100AN°ú µ¿ÀÏ

2100AN°ú µ¿ÀÏ

½Ã·á¿Âµµ

0~95¡É(32 to 203 ¢µ)

2100AN°ú µ¿ÀÏ

2100AN°ú µ¿ÀÏ

ÀÛµ¿ ½Àµµ
Operating Humidity Range

0 to 90 % RH non-condensing at  25¡É
0 to 75 % RH non-condensing at  40 ¡É

2100AN°ú µ¿ÀÏ

-

ÇÁ¸°ÅÍ

³»ÀåµÊ(28Ä÷³)

-

-

½Ã°£±â·Ï

½Ã°£³¯Â¥ Ãâ·Â

-

-

½Ã¸®¾ó ÀÔ/Ãâ·Â

RS232 serial interface via DB9 subminiature D shell connector for data output to computer or printer, and data input (command). No handshaking. Baud rate 4800, 2400, 1200, 600, or 300, one stop bit, no parity, 8-bit character length

RS232 serial interface via DB9 subminiature D shell connector for data output to computer or printer, and data input (command). No handshaking. Baud rate 1200, one stop bit, no parity, 8-bit character length

-

·¹ÄÚ´õ Ãâ·Â

0~1V

-

-

Å©±â

40.0 x 30.5 x 14.2 cm
(15.75 x 12 x 5.6")

40.0 x 30.5 x 14.2 cm
(15.75 x 12 x 5.6")

22.2 x 9.5 x 8.9 cm
(8.75 x 3.75 x 3.5")/
 3.6 kg (8 lb)

Àü¿ø

115/230 ±7%(ÀÚµ¿Àü¾Ð)
       50/60HZ

2100AN°ú µ¿ÀÏ

AÇü ¾ËÄ«¸® ¹åµ¥¸® 4°³
¶Ç´Â ¿É¼Ç ÂüÁ¶

Option

 

 

Àü¿ø¾Æ´äÅÍ-115VAC
                -230VAC

        °èÃø±âÀüü¸Þ´º 

                                  welcome to sjscale@naver.com        
                            
Àú¿ï ¹× °èÃø±â±âÀÇ ¸ðµç °Í(½ÅÁ¤Á¤¹Ð±â°è) 
            
            (Tel:055-237-5300~2,FaX:055-237-5007)